iranMadar-SmallLogo
Search
Close this search box.

FA

IMP

  • Compact internal level measurement system
  • Calibrate the system without changing  operating conditions and IP67
  • Simple LED menu settings
  • High power and narrow beam angle

The IMP series consists of non-contact level sensors from Pulsar Measurement designed to accurately and reliably determine levels. The special techniques employed in the digital echo process within the IMP level sensors make them ideal for displaying height on an LCD screen or providing analog output for communication with a control system.

Multiple measurement ranges are available, ranging from 200 millimeters to 10 meters (7.9 inches to 32.8 feet), and each sensor can be wired for either 2-wire or 3-wire operation. All IMP series sensors feature an LCD display and digital temperature measurement and compensation. The IMP level sensors can be used with PC Suite 4.0, allowing users to download, analyze, and store echo profiles, adjust sensor parameters, install firmware updates, and add a flow curve for configuring flow settings.

The IMP level measurement device is suitable for applications in water and wastewater, industrial level measurement, tank level measurement, inventory control, and compliance with health and safety regulations. For more information on the measurement range of IMP level sensors, please contact us today.

Specifications:

  • Compact and space-saving level measurement system
  • Calibration without changes and IP67 rate
  • Simple LED menu settings
  • High power and narrow beam angle
  • Dimensions: 186 mm (H) x 133 mm (D)
  • Cable entry: 2 loops, 4.5 mm to 10 mm (0.2 inches to 0.4 inches); torque up to 2 Nm
  • Installation:
  • IMP3 – 3-meter version (9.8 feet): 1.5-inch BSP/NPT
  • IMP6 – 6-meter version (19.7 feet): 1.5-inch BSP/NPT
  • IMP10 – 10-meter version (32.8 feet): 2-inch BSP/NPT
  • BSP and NPT, parallel and tapered
  • Weight: Nominal 1 kg (2.2 pounds)
  • Protection rating: IP67
  • Temperature (in Celsius): -40°C to +65°C (-40°F to +149°F)
  • Ambient temperature: -40°C to +80°C (-40°F to +176°F)
  • Input voltage range: 11-30 V, 3.5-22mA
  • Accuracy: ± 0.25% or 6 mm (0.2 inches), whichever is greater
  • Resolution: ± 0.1% or 2 mm (0.1 inches), whichever is greater
  • 5-20 mA outputs: 5 μA resolution for both active and inactive outputs
  • Temperature compensation: Achieved through internal temperature sensor with 0.5°C accuracy (±32.9°F). The process of calculating and converting levels and volumes allows for the normalization of vessel shapes.
  • Parameter values on the computer: All parameters can be accessed and modified through the PC Suite software. Monitoring and changing echo parameters can be visualized on the screen.